We fix it USB error Device Over Current Status Detected

Hello, visitor. If you've landed on this page, you've probably encountered a problem where your computer refuses to load Windows and displays the splash screen with the error:

Please enter Setup to recover BIOS Setting
USB Device Over Current Status Detected!!
Sustem Will shut down After 15 Seconds

It is a rare case when the system independently and correctly detected a malfunction. And displayed the type of breakdown directly on the screen. Inscription

USB Device Over Current Status Detected

means nothing more than a short circuit in the USB connector of the computer/laptop. What can be done about this?

The solution to a problem lies at its source.

Before you start, cancel your current BIOS settings, having de-energized the CMOS, remove the battery for a long time, simultaneously closing 2 contacts on the connector next to the battery slot labeled CLEAR CMOS. Here they are at different boards:

USB Device Over Current Status Detected: the USB device itself is damaged

The first thing the user should start with is to remove ALL devices from the USB connectors, freeing them from any flash drive, modem, transmitter, etc. Restart your computer and check if the error goes away. If the system boots normally, the reason is that the contacts of a wired mouse are shorted in the wire itself or in a connector clogged with dust. This can be easily checked by reconnecting the supposedly shorted device TO ANOTHER computer on occasion. Blow out the connectors, which, however, does not always work: dust can clog not only the contacts themselves in the connector, but also the space around the slot motherboard at the junction of the connector to the motherboard. There is only one way out: open the computer/laptop and use a brush to go over all the places where the USB connectors are attached.

USB Device Over Current Status Detected: connector damage

Yes, USB connectors on a computer are one of the weakest points: we constantly plug flash drives, external drives, modems... This is not always done carefully and there is no exact time when one of the contacts in the connector “falls”. The result will be the unexpected appearance of the indicated inscription and the shutdown of the computer, which thus protects the motherboard from damage. Exit: with the roof open and a clear view of the board, carefully inspect each of the connectors for visible damage and contacts that have fallen on each other. I will supplement the article with a specific example later.

USB Device Over Current Status Detected: Check the jumpers on the board

According to some incomprehensible logic, component manufacturers, and more often assemblers in the workshop, incorrectly (or even never) read the manuals for the equipment being installed. As a result, incorrectly set short circuits or jumpers for correct operation equipment. The system works more or less smoothly until the first failures, associated primarily with the physical aging of the equipment or improper operating conditions: dust, vibration, expiration of components. At some point, this is accompanied by signal attenuation, loss of communication between electronic components, and the appearance of incorrect self-diagnosis signals. In the end, we have what we have. Output: Check the jumpers on the connectors labeled USBPWR, USBPOWER, etc. Where there is no jumper, BE SURE TO INSTALL. Didn't work? Check that the board is firmly attached to the case and that there are no oxidized areas at the mounting points.

USB Device Over Current Status Detected: USB cables are shorting

There are some in your computer case, and they can also collect dirt and dust or fray at kinks. Reconnect the cables.

This is all you can do at home. Good luck.

If, after turning on, your computer turns off by itself, and on the screen you see the error message USB device over current status detected System will shut down after 15 seconds, this indicates that there are problems with USB operation (overcurrent protection is turned on) , however, a novice user cannot always figure out what is wrong and how to fix the problem.

This manual contains details about simple ways fix the USB device over current status detected error followed by automatic shutdown of the computer.

The next most common reason is Damaged USB connectors. If you frequently use a particular USB connector, for example, by plugging and unplugging a flash drive every day (the connectors on the front panel of the computer most often suffer), this may also cause a problem.

Even in cases where visually everything is in order with the connectors, and you do not use the front connectors, I recommend trying to disconnect them from the motherboard, very often this helps. To disconnect, turn off the computer, including from the network, open the case, and then disconnect the cables leading to the front USB connectors.

About what they look like and how they are signed - in the instructions, in the section “ USB connection ports on the front panel."

Sometimes the cause of the USB device over current status detected error can be a damaged or removed USB power jumper, usually labeled as USB_PWR, USB POWER or USBPWR (there may be more than one, for example: one for the rear USB connectors, for example, USBPWR_F, one - for the front ones - USBPWR_R), especially if in Lately you did some work inside the computer case.

Try to find these jumpers on the computer motherboard (located close to the USB connectors to which the front panel is connected from the previous step) and install them so that they close pins 1 and 2, and not 2 and 3 (and if they are missing altogether and not installed - install them in place).

Essentially, these are all methods that work for simple error cases. Unfortunately, sometimes the problem can be more serious and more difficult to fix on your own:

  • Damage to the electronic components of the motherboard (due to voltage surges, improper shutdown, or simple failure over time).
  • Damage to the rear USB connectors (requires repair).
  • Rarely - malfunction of the computer power supply.

Among other tips on the Internet on the topic of this problem, you can find, but in my practice this is rarely effective (unless you performed a BIOS/UEFI update immediately before the error appeared).

Warning! USB device over current status detected! System will shut down after 15 seconds is an error message that may appear when you try to turn on your computer or laptop. This error indicates problems in USB operation and stops the computer from booting. In this article, we will look at the main reasons that can lead to this error, and also tell you how to eliminate them and restore the computer boot.

The error is caused by a faulty USB device or cable

If you receive the error “USB device over current status detected System will shut down after 15 seconds”, then the first thing to do is check the USB devices that are connected to the computer. Most likely, one of these devices is faulty and causes this error to appear.

To check this, disconnect all USB devices (including flash drives) from the computer and try turning them on again. If after this the “USB device over current status detected” error disappears or some other error appears instead (for example, with a message that the keyboard is not connected), then this means that you are on the right track, the problem is in one of your USB devices.

If you have disconnected all USB devices and realized that without them there is no problem, then you next need to determine which device is causing the problem. This can be done by connecting the devices one at a time and trying to turn on the computer.

For example, we connected a keyboard and tried to boot the computer. If it boots, then the keyboard is working. Next we try to connect the mouse. And so on until the computer again gives the error USB device over current status detected. The device on which the error appeared is the problem.

You need to understand that an error can be caused not only by the USB device itself, but also by the cable with which it is connected. Therefore, after you have determined faulty device, try connecting it using another USB cable. If the problem is not reproduced with another cable, then the problem lies with that cable. Replace the cable and continue using the device.

The error is caused by a damaged USB power connector or jumper

If you have checked all connected to computer USB devices and could not find the source of the problem, then Next you need to check the USB connectors. Perhaps one of the connectors is damaged and when connecting a device to it, it causes an error to appear“USB device over current status detected System will shut down after 15 seconds.” In particularly advanced cases, a damaged connector can cause an error even without connecting devices.

To check this option, you need to carefully inspect all USB connectors, both on the front panel and on the back of the computer (on the motherboard). If a damaged connector is found, then most likely that is the problem.

Damaged connectors on the front panel are quite easy to deal with. You need to completely turn off the computer, remove the side cover and disconnect the cable that goes from the motherboard to the USB connectors on the front panel of the computer. This way you will disconnect the damaged connector from the computer and it will no longer cause problems.

With damaged connectors on the motherboard itself, everything is more complicated. You can try to fix such a connector yourself, but there is a risk of making it even worse and burning the motherboard the next time you turn on the computer. Therefore, to solve this problem it is better to find service center, which repairs motherboards.

In addition, the “USB device over current status detected” error may occur due to the absence or incorrect position power supply jumpers USB connectors . These jumpers may be called USB_PWR, USBPWR, or USB POWER. In some cases, there are two of them on the board (Front and Rear).

To find the location of the front USB connectors or the location of the USB power jumpers, use the instructions that came with your motherboard.

Other reasons for the error USB device over current status detected

The problems described above are the most likely reasons for the error “USB device over current status detected System will shut down after 15 seconds” to appear when the computer boots. But, in rare cases, other problems are possible:

  • Damage to chips on the motherboard. As a result of a short circuit or voltage drop, some chips on the motherboard may fail. In such a situation, a variety of errors and problems may appear in the operation of the computer.
  • Problems with the power supply. In some cases, the appearance the specified error can be brought from incorrect work computer power supply.
  • Problems with BIOS. In some cases, the problem may occur as a result of a failed BIOS firmware update.

(5 votes, average: 5,00 out of 5)


I turn on the computer and a recording comes out usb device over current status detected system will shutdown in 15 seconds, what does it mean? Translated, this roughly sounds like “A USB device with high current consumption has been detected, the system will reboot in 15 seconds.”

If the error usb device over current status detected appears, you should not immediately open the case of the system unit; first, let’s inspect USB port s your computer.

How to remove the message usb device over current status detected system will shutdown in 15 seconds

  1. Since the message says about a USB device error, let's start by disconnecting all USB devices on the computer, such as USB flash drives, USB cameras, mice, keyboards and other USB devices (you need to free all USB ports on the computer from connected external devices). We turn on the computer and see that the usb device over current status detected error has disappeared, if not, then go to the second point. If the message disappears, then the reason for the appearance of this message is a faulty connected USB device (the wire is broken, there is a short circuit - replace the faulty USB device with a new one).
  2. If, after disconnecting all USB devices, the usb device over current status detected message is still an eyesore, then you need to inspect all USB ports for broken parts, foreign objects, and even dust inside the ports. There were cases when, after cleaning the USB ports from dust, the usb device over current status detected message disappeared.
  3. In 90 percent of cases, as a rule, a broken connector is identified at the second stage. Which USB ports are used most often? Those located on the front panel of the system unit case. And even if you were unable to identify a faulty USB port, do not despair, disabling USB front panel ports will help in most cases.

Conclusion. The error is typical for ASUS motherboards, and it is not always worth seeking the help of a specialist to resolve errors when turning on the computer, and even with minimal knowledge of computer devices, some problems can be solved by an ordinary user on their own. And if the described actions did not help you eliminate the reason for the appearance of the message usb device over current status detected, then Possible Solution your problem is this:

  • Check the USBPWR power management jumper; the absence of this jumper on the motherboard may also be the reason for the appearance of the message when starting the computer
  • Malfunction of the resistor identifying the presence of voltage on one of the ports

Some users, when turning on the computer, may see a message on their monitors - USB Device Over Current Status Detected. Translated from English, this means that a USB device with high electricity consumption has been detected. If this error appears, do not immediately open the inspection cover. Try to inspect the external part of the system unit without touching it.

Solutions for USB Device Over Current Status Detected error


Most often, after the 2nd step of applying the cause elimination, the computer begins to work stably. First of all, you need to try the USB ports that are most often used. Typically, these are ports located on the front panel of the computer, take a closer look at them, you may be able to notice shades of carbon deposits, in this case the port is most likely burned out from overvoltage or improper operation. Even if you are unable to visually determine the failure, then sequentially disconnecting the devices should definitely resolve the issue with the error - USB Device Over Current Status Detected.

Other reasons for errors with USB

According to statistics, this error most often occurs on motherboard models. Asus. For some errors, including this one, there is no need to immediately contact specialists from the service, because at least half of them any average user can solve on their own at home. If the above tips did not work for you and the error has not gone away, then you may need to try a few more tips:

  • You need to reset the BIOS settings. This can be done in several ways: programmatically, using the CLRTC jumper, and also by removing the battery motherboard. You can read more about these methods on the Internet, each for its own model.
  • Make sure that the motherboard has a USBPWR power management jumper; if it is not present, this may cause a USB Device Over Current Status Detected error when turning on the computer.
  • The resistor that checks for voltage on the required port may be faulty, which is the cause of the error described above.

Checking the motherboard

The problem may also lie in the motherboard. Sometimes board manufacturers make various errors during production, as a result of which they can lead to serious consequences, unstable operation of ports and even short circuits.

The USB Device Over Current Status Detected error occurs when the shorts and jumpers are placed incorrectly. This leads to the fact that the system works stably for some time, until the first failure and then all sorts of errors begin related to the operation of plug-ins. In addition to the factory flaw, the motherboard becomes covered in dust after some time. This is all accompanied by a muted signal, failures in the communication of the motherboard components, and also by the fact that the system tries to diagnose itself upon startup.


  • Next, with the computer completely turned off and de-energized, open the inspection cover and carefully examine the system board.
  • Inspect the jumpers in the USBPOWER and USBPWR connectors. If they are missing, you must install them.
  • It is also necessary to check where the board is attached to system unit, check these areas for oxidation areas.
  • Check all ports and major components on the motherboard, you may be able to see scorched areas, these may be the result of a short on the port.

The cables also need to be checked at bending areas. Perhaps in one of these areas one or more wires are broken. In this case, the motherboard comes with additional cables; if there are none, you will have to buy new ones and replace them. If the cables are fine, try disconnecting them. Sometimes the contacts become clogged with dust and stop transmitting the signal. They need to be removed from the nest, blown out and put back in place. After that, put everything in place and tighten it.